Smart Water Flow Control and Monitoring
Solenoid Valve Controller
IP68 Rated Enclosure for Harsh Environment
Internal and External Antenna Versions Optional
Data Integrity and Reliability
Easy Configuration via NFC
Milesight D2D
Solenoid Valve Control
Autonomous Operation
Flexible Power Supply Options
Support Multicast for Control in Bulk
Empower Automatic & Precise Irrigation
The UC51x Series is a LoRaWAN® Solenoid Valve Controller that facilitates automatic and precise irrigation. By seamlessly integrating with smart irrigation systems, it enables flexible irrigation strategies based on factors like time, volume, or soil moisture
Solenoid Valve Control
Equipped with 2 Outputs for Connecting 2 DC Latching Solenoid Valve
Time-Based Control
Volume-Based Control
Moisture-Based Control (Collaborating with EM500-SMTC)
Up to 16 Schedule Events
Supporting different typs of control mode
You can determine the valve, irrigation timing, and water usage
in each rule engine
Programmable Unit per Pulse
One-time scheduled irrigation
Periodic Irrigation within Pre-determined Period
Trigger through Milesight D2D
Trigger through pre-determined conditions
Real-time Alarming
Every increase of water volume over threshold
Accumulated Water volume within pre-detemined period over Threshold
Water Flow Monitoring
Equipped with 2 Digital Inputs for Connecting Pulse Water Meters
Programmable Unit per Pulse
Enable Precise Irrigation
Flexible Power Supply
Solar-powered or battery-powered? It all depends on your needs
Ultra-Rugged Enclosure for Harsh Environment
The UC51x Series features an IP68 rated enclosure and an M12 connector that offer robust protection against water ingress, corrosion, and vibrations. This combination of features ensures long-term, dependable operation in challenging all-weather environments
Autonomous Operation
The UC51x Series can execute the preset commands autonomously even when the network is unavailable
Multicast for Control in Bulk
By utilizing multicast, users can efficiently configure a group of devices in bulk. This feature streamlines the setup process, making it effortless to simultaneously manage multiple UC51x Controllers and enabling batch solenoid valve control, ultimately saving time and effort
Internal and External Antenna Versions
The UC51x Series provides flexibility in antenna placement, ensuring optimal signal strength and range, even in environments with obstacles or challenging RF conditions
Smart Agriculture Kit
Remote Monitoring and Control
Seamlessly integrating cutting-edge hardware and advanced software, this kit offers unparalleled IoT connectivity. Gain instant access to valuable data insights, advanced analytics, and immersive visualization tools that will revolutionize your farming practices
LoRaWAN® Based
Penetrating Signals: data transmission range up to 2 km in urban areas and
15 km in rural areas
High Compatibility: compliant with standard LoRaWAN® gateways and network servers
Store Capacity with 2,800 Sets of Historical Data Records
Data can be stored in the device and cannot be manually deleted, further securing the traceability of the reported information
Support Retransmission for Reliable Communication
With support for data retransmission,the device guarantees that the web server gets all the data even if the network is down occasionally
Milesight D2D Communication
Milesight D2D (Device to Device) protocol featuring LoRa enables the communication among different Milesight LoRaWAN® node devices without a LoRaWAN® gateway. Meanwhile, UC511 can work as a D2D Agent in Class C mode. (Note: UC512 doesn’t support Milesight D2D)
Lower Latency
Less Than 1 Second Response Time
Reduce Investment Cost
Related Products
UC511/UC512
LoRaWAN® Solenoid Valve Controller
UC300
IoT Controller
| Technology | LoRaWAN®, Milesight D2D |
| Antenna | Internal Antenna or External Antenna (Hardware Optional) External Antenna (EA) Version: 1 × 50 Ω SMA Female Connector |
| Frequency | CN470/IN865/EU868/RU864/US915/AU915/KR920/AS923-1&2&3&4 |
| Tx Power | 16dBm(868MHz)/20dBm(915MHz)/19dBm(470MHz) |
| Sensitivity | -137dBm @300bps |
| Mode | OTAA/ABP Class A, Class B, Class C, Class C to B |
| Data Interfaces | |
| Interface Type | M12 A-Coded Male |
| Solenoid Interface | |
| Ports | 2 × Solenoid Interfaces |
| Solenoid Support | 2 Wires DC 12V Latching Solenoids |
| Cable Length | 1.5m (by Default) |
| GPIO Interface | |
| Ports | 2 × Digital Inputs, Dry Contact |
| Logical Level | Low: 0~0.8 V, High: 2.5~3.3 V |
| Maximum Current | 20 mA |
| Work Mode | Digital Input, Pulse Counter |
| Input Frequency | Suggested value: ≤ 4000 Hz |
| Others | |
|---|---|
| LED | 1 × LED Indicator (Interna1 × Reboot/Reset (Internal)l) |
| Button | 1 × Power/Reset Button (Internal) |
| USB | 1 × USB Type-C(Internal) for Configuration and Console |
| Power Connector | 1 × M12 A-Coded Male Interface (EA Version Only) |
| Software | |
| Power On & Off | Mobile App via NFC, Power Button (Internal), Cable Connection |
| Configuration | Mobile App via NFC |
| Advanced Feature | Multicast, Data Storage (500 entries), Data Retransmission, Data Retrievability, Milesight D2D Agent, Local Rules |
| Physical Characteristics | |
| Power Supply | 1.Embedded Solar Power (6V, 1.7W) 2.2 × 2550 mAh ICR18650 Chargeable Batteries 3.DC 5-24 V by Power Connector (EA Version Only) |
| Battery Life*(20 min interval + control valve 4 times per day, 25°C) | When battery level is full and does not charge: Class A: Around 8.4 years (SF7), Around 3.3 years (SF10) Class B: Around 1.1 year Class C: Around 26 days |
| Operating Temperature | -20°C~60°C |
| (10 min interval, 25 °C) | Up to 10 years (SF7, US915) Around 8 years(SF10, US915) |
| Operating Temperature | -30°C~70°C |
| Relative Humidity | 0 ~ 95% (Non-condensing) |
| Ingress Protection | IP68 (1m underwater, 7 days) |
| Housing&Color | Transceiver: ABS + PC, Grey Soil Sensor: Epoxy Resin + Stainless Steel, White + Silver |
| Weight | IA Version: 425g EA Version: 467g |
| Dimension | 116 × 116 × 45.5 mm (4.56 × 4.56 × 1.79 in) (Connectors Excluded) |
| Installation | Wall or Pole Mounting |
| Approvals | |
| Regulatory | CE, FCC |
| Environmental | RoHS |
| Technology | LoRaWAN® |
| Antenna | Internal Antenna or External Antenna (Hardware Optional) External Antenna (EA) Version: 1 × 50 Ω SMA Female Connector |
| Frequency | CN470/IN865/EU868/RU864/US915/AU915/KR920/AS923-1&2&3&4 |
| Tx Power | 16dBm(868MHz)/20dBm(915MHz)/19dBm(470MHz) |
| Sensitivity | -137dBm @300bps |
| Mode | OTAA/ABP Class A, Class B, Class C, Class C to B |
| Data Interfaces | |
| Interface Type | M12 A-Coded Male |
| Solenoid Interface | |
| Ports | 2 × Solenoid Interfaces |
| Solenoid Support | 2 Wires DC 12V Latching Solenoids |
| Cable Length | 1.5m (by Default) |
| GPIO Interface | |
| Ports | 2 × Digital Inputs, Dry Contact |
| Logical Level | Low: 0~0.8 V, High: 2.5~3.3 V |
| Maximum Current | 20 mA |
| Work Mode | Digital Input, Pulse Counter |
| Input Frequency | Suggested value: ≤ 4000 Hz |
| Others | |
|---|---|
| LED | 1 × LED Indicator (Interna1 × Reboot/Reset (Internal)l) |
| Button | 1 × Power/Reset Button (Internal) |
| USB | 1 × USB Type-C(Internal) for Configuration and Console |
| Power Connector | - |
| Software | |
| Power On & Off | Mobile App via NFC, Power Button (Internal), Cable Connection |
| Configuration | Mobile App via NFC |
| Advanced Feature | Multicast, Data Storage (500 entries), Data Retransmission, Data Retrievability, Milesight D2D Agent, Local Rules |
| Physical Characteristics | |
| Power Supply | 3 × 9000 mAh Replaceable ER26500 Li-SOCL2 Batteries |
| Battery Life*(20 min interval + control valve 4 times per day, 25°C) | Class A: >10 years Class B: Around 6.2 years (SF7), Around 5.8 years (SF10) |
| Operating Temperature | -30°C~70°C |
| Relative Humidity | 0 ~ 95% (Non-condensing) |
| Ingress Protection | -30°C~70°C |
| Relative Humidity | 0 ~ 95% (Non-condensing) |
| Ingress Protection | IP68 (1m underwater, 7 days) |
| Dimension | 116 × 116 × 45.5 mm (4.56 × 4.56 × 1.79 in) (Connectors Excluded) |
| Weight | IA Version: 479g EA Version: 571g |
| Installation | Wall or Pole Mounting |
| Approvals | |
| Regulatory | CE, FCC |
| Environmental | RoHS |
Documents
"*" indicates required fields